dt-bindings: phy: rockchip: rk3588 has two reset lines


The RK3588 has two reset lines for the combphy. One for the
APB interface and one for the actual PHY.

Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent b64506f0
No related branches found
No related tags found
No related merge requests found
...@@ -31,8 +31,13 @@ properties: ...@@ -31,8 +31,13 @@ properties:
- const: pipe - const: pipe
resets: resets:
minItems: 1
maxItems: 2
reset-names:
items: items:
- description: exclusive PHY reset line - const: phy
- const: apb
rockchip,enable-ssc: rockchip,enable-ssc:
type: boolean type: boolean
......